BALLUFF BES000U FEATURES
- Connection: Cable, 2.00 m, PUR
- Operating temperature: -25 to 70 °C, Temperature drift max. (% Sr) > 15% valid from 50 to 70 °C
- IP rating: IP68
- Shielded and unshielded versions
- Plug or cable connection
Over 40 Years in Business
Successful track record across Canada
Full Engineering Services
A powerhouse to provide consultation, training, and support
Strong Brand Portfolio
Top-notch products from superb global and local suppliers
Advanced Technologies
From legacy and mainstream to advanced Industry 4.0
BALLUFF BES000U INTRODUCTION
Balluff BES standard inductive sensors for detecting electrically conductive metallic objects are robust and reliable. With a wide range of over 500 model series, we offer the right inductive sensor for every application.
The technology, which is in use worldwide, has an optimum price/performance ratio and can also be delivered in a short amount of time even in large quantities.
BALLUFF BES000U CERTIFICATIONS
Sensor : Basic features | |
Approval/Conformity | CE, UKCA, cULus, WEEE |
Basic standard | IEC 60947-5-2 |
Sensor : Display/Operation | |
Function Indicator | Yes |
Power Indicator | No |
Sensor : Electrical Connection | |
Cable diameter D | 3.00 mm |
Cable length L | 2 m |
Number of conductors | 3 |
Sensor : Electrical Data | |
Operating Voltage Ub | 10 to 30 VDC |
Output Resistance Ra | 33.0 kOhm |
Protection Class | II |
Switching Frequency | 4000 Hz |
Sensor : Environmental Conditions | |
EN 60068-2-27, Shock | Half-sinus, 30 g , 11 ms |
EN 60068-2-6, Vibration | 55 Hz, amplitude 1 mm, 3x30 min |
Sensor : Functional Safety | |
MTTF (40 °C) | 595 a |
Sensor : Interface | |
Switching Output | PNP normally closed (NC) |
Sensor : Material | |
Housing Material | Stainless steel |
Material Jacket | PUR |
Material Sensing Surface | PBT |
Sensor : Mechanical Data | |
Dimension | Ø 8 x 30 mm |
Installation | non-flush |
Size | M8x1 |
Sensor : Range/Distance | |
Assured Operating Distance Sa | 3.2 mm |
Rated Operating Distance Sn | 4 mm |
Real Switching Distance sr | 4 mm |