Introduction


Balluff BHS pressure-rated inductive sensors withstand pressures up to 500 bar. They are perfectly suited for monitoring the position of your hydraulics, such as when controlling the end position of hydraulic cylinders or monitoring valve positions.


Their durability is made possible by media-resistant housing materials and a special sealing process. For your individual applications, we offer a comprehensive range of product configurations with different housing diameters and thread sizes.


Certifications

    


Features


  • Connection: Cable, 2.00 m, PUR
  • Operating temperature: -25 to 70 °C
  • IP rating: IP67
  • Pressure rating max: 10 bar 
  • Short and long configurations
  • With and without fixed stop
Sensor : Basic features
Approval/Conformity CE, UKCA, cULus, WEEE
Basic standard IEC 60947-5-2
Sensor : Display/Operation
Function Indicator Yes
Power Indicator No
Sensor : Electrical Connection
Cable diameter D 3.00 mm
Cable length L 2 m
Number of conductors 3
Sensor : Electrical Data
Operating Voltage Ub 10 to 30 VDC
Output Resistance Ra Open collector
Protection Class _
Switching Frequency 3000 Hz
Sensor : Environmental Conditions
EN 60068-2-27, Shock Half-sinus, 30 g , 11 ms
EN 60068-2-6, Vibration 55 Hz, amplitude 1 mm, 3x30 min
Sensor : Functional Safety
MTTF (40 °C) 830 a
Sensor : Interface
Switching Output PNP normally open (NO)
Sensor : Material
Housing Material Stainless steel
Material Jacket PUR
Material Sensing Surface Ceramic
Sensor : Mechanical Data
Dimension Ø 5 x 42 mm
Installation for flush mounting
Size M5x0.5
Sensor : Range/Distance
Assured Operating Distance Sa 0.65 mm
Rated Operating Distance Sn 0.8 mm
Real Switching Distance sr 0.8 mm