BALLUFF BHS004L PRESSURE-RATED/ FOR HAZARDOUS AREAS INDUCTIVE SENSORS
BALLUFF BHS004L PRESSURE-RATED/ FOR HAZARDOUS AREAS INDUCTIVE SENSORS
- Model: BHS004L
$0.00
Ex Tax: $0.00
Over 40 Years in Business
Successful track record across Canada
Full Engineering Services
A powerhouse to provide consultation, training, and support
Strong Brand Portfolio
Top-notch products from superb global and local suppliers
Advanced Technologies
From legacy and mainstream to advanced Industry 4.0
Introduction
Balluff BHS pressure-rated inductive sensors withstand pressures up to 500 bar. They are perfectly suited for monitoring the position of your hydraulics, such as when controlling the end position of hydraulic cylinders or monitoring valve positions.
Their durability is made possible by media-resistant housing materials and a special sealing process. For your individual applications, we offer a comprehensive range of product configurations with different housing diameters and thread sizes.
Certifications
Features
- Connection: M12x1-Male, 4-pin, A-coded
- Operating temperature: -25 to 70 °C
- IP rating: IP68
- Pressure rating max: 500 bar
- Interface: NAMUR
- Base type deviation: Housing, Pin assignment
- Short and long configurations
- With and without fixed stop
Sensor : Basic features | |
Approval/Conformity | CE, UKCA, CCC Ex, IECEx, ATEX, WEEE |
Basic standard | EN 60079-0, EN 60079-11,IEC 60079-0, IEC 60079-11, IEC 60947-5-6 |
Sensor : Display/Operation | |
Function Indicator | No |
Power Indicator | No |
Sensor : Electrical Connection | |
Cable diameter D | _ |
Cable length L | _ |
Number of conductors | _ |
Sensor : Electrical Data | |
Operating Voltage Ub | 7.7 to 9 VDC |
Output Resistance Ra | _ |
Protection Class | _ |
Switching Frequency | 1000 Hz |
Sensor : Environmental Conditions | |
EN 60068-2-27, Shock | Half-sinus, 30 g , 11 ms |
EN 60068-2-6, Vibration | 55 Hz, amplitude 1 mm, 3x30 min |
Sensor : Functional Safety | |
MTTF (40 °C) | 9720 a |
Sensor : Interface | |
Switching Output | _ |
Sensor : Material | |
Housing Material | Stainless steel |
Material Jacket | _ |
Material Sensing Surface | POM |
Sensor : Mechanical Data | |
Dimension | Ø 12 x 56 mm |
Installation | for flush mounting |
Size | M12x1 |
Sensor : Range/Distance | |
Assured Operating Distance Sa | 1.1 mm |
Rated Operating Distance Sn | 1.5 mm |