MOXA TN-5816ABP-WV-T FEATURES
- Layer 3 routing interconnects multiple LAN segments
- Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy
- Complies with all EN 50155 mandatory test items
- 12 x 10/100BaseT(X) Ports (M12 connector)
- 4 x 10/100BaseT(X) Ports (M12 connector with Bypass Relay)
- 24 to 110 VDC isolated dual power inputs
- DIN-rail and wall mounting
- -40 to 75°C operating temperature

Over 40 Years in Business
Successful track record across Canada

Full Engineering Services
A powerhouse to provide consultation, training, and support

Strong Brand Portfolio
Top-notch products from superb global and local suppliers

Advanced Technologies
From legacy and mainstream to advanced Industry 4.0
MOXA TN-5816ABP-WV-T INTRODUCTION
The ToughNet TN-5800A Series switches are high-performance M12 Layer 3 Ethernet switches that support Layer 3 routing to facilitate the deployment of applications across networks. By using M12 and other circular connectors, the TN-5800A Series ensures tight, robust connections and reliability against environmental disturbances, such as vibration and shock. TN-5800A Series switches provide isolated power with a 24 to 110 VDC power input range, which allows you to use the same model at different sites around the globe.
In addition, TN-5800A Series switches provide up to 16 Fast Ethernet M12 ports with 4 bypass relay ports, and 2 Gigabit Ethernet ports with bypass relay function. Furthermore, the -40 to 75°C operating temperature and IP54-rated water and dust-resistant enclosure allow deployment in harsh environments. The TN-5800A Series Ethernet switches are compliant with mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the switches suitable for a variety of industrial applications.
As an Authorized Distributor of MOXA, Manufacturers Automation Inc. (ManuAuto) offers a wide variety of Industrial Automation and Communication products across North America, including Canada (Ontario, Toronto) and the US. Buy MOXA TN-5816ABP-WV-T Managed Ethernet Switch online at a competitive price, with on-time delivery and fast shipping services. Our certified engineers are always available to support you.
End-of-Life Product - Replacement Available
Please note that the TN-5800A Series has been phased out and replaced by the TN-4916 Series.
MOXA TN-5816ABP-WV-T CERTIFICATION
Switch and Hub : Interface | |
Number of ports | 16 Ports |
10/100Mb RJ45 (Megabit) Ports | No |
10/100/1000Mb RJ45 (Gigabit) Ports | No |
100Mb Fiber optic multi mode (Megabit) Ports | No |
100Mb Fiber optic single mode (Megabit) Ports | No |
1000Mb SFP Fiber optic (Gigabit) Ports | No |
10/100Mb (Megabit) POE Ports | No |
100Mb SFP Fiber optic (Megabit) Ports | No |
10/100/1000Mb (Gigabit) POE Ports | No |
Other ports | 2 x 10/100/1000BaseT(X) ports (M12 X-coded 8-pin female connector with bypass relay), 12 x 10/100BaseT(X) ports (M12 D-coded 4-pin female connector) |
Switch and Hub : Features and Capabilities | |
Backup | Yes: ABC-01-M12 |
Switch and Hub : LED Indicators | |
LED Per Port | Yes |
Switch and Hub : Power Requirements | |
Input Voltage | 24/36/48/72/96/110 VDC |
Input Current | 1.1 A @ 24 VDC, 0.23 A @ 110 VDC |
Operating Voltage | 16.8 to 137.5 VDC |
Power Input Plugin ( Redundant ) | Yes |
Switch and Hub : General | |
Fan / Fanless | Fanless |
MTBF | 577,026 hrs |
Switch and Hub : Switch Specifications | |
Most forwarding speed | - |
Network working layers | Layer 3 |
Switch type | Managed |
Port Aggregation | - |
Switch and Hub : Physical Characteristics | |
Dimensions | 250 x 181.4 x 115 mm (9.84 x 7.14 x 4.53 in) |
Housing | Metal |
Installation | DIN-rail mounting (optional), Wall mounting (standard) |
Operating Temperature | -40 to 75°C (-40 to 167°F) |
Operation Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | Safety: UL/cUL 508, EN 60950-1, EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A, IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m, IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: 10 V, IEC 61000-4-8, Rail Traffic: (for panel-mounting installations) EN 50155 (essential compliance*), EN 50121-4, EN 45545-2, Shock: EN 50155, IEC 61373, Freefall: IEC 60068-2-32, Vibration: EN 50155, IEC 61373, Telcordia SR332, IP54 protection |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Switch and Hub : Standards and Protocols | |
Protocols and work standards | IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) ,IEEE 802.3ab for 1000BaseT(X) ,IEEE 802.3x for Flow Control ,IEEE 802.1D-2004 for Spanning Tree Protocol ,IEEE 802.1w for Rapid Spanning Tree Protocol ,IEEE 802.1s for Multiple Spanning Tree Protocol ,IEEE 802.1Q for VLAN Tagging ,IEEE 802.1p for Class of Service ,IEEE 802.1X for Authentication ,IEEE 802.3ad for Port Trunk with LACP, Industrial Protocols: EtherNet/IP, Modbus/TCP, MIB: MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge, MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9, Routing Redundancy: VRRP |
Protocols and management standards | IPv4, SNMP v1/v2c/v3, Telnet, LLDP, Port Mirror, Syslog, RMON, BootP, DHCP Server/Client, DHCP Option 66/67/82, TFTP, SMTP, RARP, HTTP, HTTPS, SNMP inform, Flow Control, Back pressure flow control, Time Management: SNTP, NTP Server/Client, IEEE 1588v2 PTP |
Switch and Hub : Package Checklist | |
Hardware installation guide | Yes |
Power adapter | No |