Introduction
The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the switches suitable for a variety of industrial applications.
Certifications
Features
- 1 x 10/100Mbps T(x) port and 1 x 100Mbps F(x) multi-mode port with SC connector
- 85-264 VAC/ 88-300 VDC input power
- Metal body
- -40 to 85°C operating temperature
eth to fiber : Interface | |
10/100BaseT(X) Ports | 1 |
100BaseFX Ports | 1 x Multi-mode SC |
Magnetic Isolation Protection | 1.5 kV (built-in) |
eth to fiber : General | |
MTBF | 1,211,613 hrs |
eth to fiber : Power Requirements | |
Input Voltage | HV-AC : 85 to 264 VAC, HV-DC : 88 to 300 VDC |
Input Current | HV-AC : 73 mA @ 85 VDC, HV-DC : 47 mA @ 88 VDC |
Overload Current Protection | Yes |
Power Consumption | HV-AC : 73 mA @ 85 VDC, HV-DC : 47 mA @ 88 VDC |
eth to fiber : Physical Characteristics | |
Housing | Metal |
Dimensions | 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Weight | Packaged: 875 g (1.92 lb), Product only: 690 g (1.52 lb) |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Operation Humidity | 5 to 95% (non-condensing) |
Installation | DIN-rail mounting |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV, IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV, IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m, IEC 61000-4-8 PFMF, IEC 61000-4-11 DIPs |
Safety | EN 60950-1, UL 60950-1 |
Vibration | IEC 60068-2-6 |