MOXA TCC-100-T RS-232 to RS-422/485 Converter
MOXA TCC-100-T RS-232 to RS-422/485 Converter
- Model: TCC-100-T
$0.00
Ex Tax: $0.00
Over 40 Years in Business
Successful track record across Canada
Full Engineering Services
A powerhouse to provide consultation, training, and support
Strong Brand Portfolio
Top-notch products from superb global and local suppliers
Advanced Technologies
From legacy and mainstream to advanced Industry 4.0
Introduction
The TCC-100/100I Series of RS-232 to RS-422/485 converters increases networking capability by extending the RS-232 transmission distance. Both converters have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, an external terminal block for power, and optical isolation (TCC-100I and TCC-100I-T only). The TCC-100/100I Series converters are ideal solutions for converting RS-232 signals to RS422/485 in critical industrial environments.
Certifications
Features
- RS-232 to RS-422 conversion with RTS/CTS support
- RS-232 to 2-wire or 4-wire RS-485 conversion
- Metal housing
- -40 to 85°C operating temperature
Serial Converters : RS-232 port specifications | |
Serial connection type | DB9 female |
Signal | TxD, RxD, RTS, CTS, GND |
Serial Converters : RS-422/RS-485 port specifications | |
Serial connection type | Terminal input |
Signal | TxD+, TxD-, RxD+, RxD-, RTS, CTS, GND Data+, Data |
RS-485 Flow Control | ADDC |
Serial Converters : Converter Specifications | |
Data transfer speed ( Baudrate ) | 0.05Kbps to 921.6Kbps |
Protection against electrostatic discharge | 4KV |
Electrical isolation | No |
Serial Converters : Power Requirements | |
Type of power input | Terminal input |
Input Power | 12V DC to 48V DC, 0.15A |
Power Consumption | 12V DC, 0.15A |
Protection against reverse voltage | Yes |
Protection against overflow | Yes : Protection against two short signals |
Serial Converters : Physical Characteristics | |
Dimensions | 67x100.4x22mm |
Standards and Certifications | Safety: UL 60950-1; EMC: EN 55032/24; EMI:CISPR 32, FCC Part 15B Class B; EMS: EN 61000-4-2 (ESD): Contact: 4 kV; Air: 8 kV, EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m, EN 61000-4-4 (EFT): Power: 1 kV; Signal: 0.5 kV, EN 61000-4-5 (Surge): Power: 1 kV, EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m, EN 61000-4-8 (PFMF); Green Product: RoHS, CRoHS, WEEE; |
Housing | Metal |
Operating Temperature | -40 to 85 ° C |
Storage Temperature | -40 to 85 ° C |
Operation Humidity | 5% to %95 non-condensing |
Weight | 0.148Kg |