BALLUFF BES05L4 INDUCTIVE SENSORS FOR HAZARDOUS AREAS
BALLUFF BES05L4 INDUCTIVE SENSORS FOR HAZARDOUS AREAS
- Model: BES05L4
$0.00
Ex Tax: $0.00
Over 40 Years in Business
Successful track record across Canada
Full Engineering Services
A powerhouse to provide consultation, training, and support
Strong Brand Portfolio
Top-notch products from superb global and local suppliers
Advanced Technologies
From legacy and mainstream to advanced Industry 4.0
Introduction
Balluff offer inductive sensors for all Ex zones. Applications for these wear-free switches range from Zone 2/22, in which an explosive atmosphere rarely occurs (Category 3G/3D), to Zone 0/20, where the greatest explosion hazard is present.
With many sensor styles, Balluff serve a broad range of applications so that you can handle a wide variety of requirements. The comprehensive portfolio includes, for example, pressure rated sensors up to 500 bar or sensors with extended temperature range — all in a variety of housing styles. The appropriate accessories, such as NAMUR switching amplifiers or single-ended cordsets, are also available.
Certifications
Features0M
- Connection: Cable, 2 m, PUR
- Operating temperature: -20 to 60 °C
- IP rating: IP67
- For zones: 0, 1, 2, 20, 21 and 22
- Non-contacting
- Media-resistant
- Impervious to contamination
Sensor : Basic features | |
Approval/Conformity | CE, IECEx, ATEX, WEEE |
Basic standard | EN 60079-0, EN 60079-18, IEC 60947-5-2 |
Sensor : Display/Operation | |
Function Indicator | _ |
Power Indicator | _ |
Sensor : Electrical Connection | |
Cable diameter D | _ |
Cable length L | 2 m |
Number of conductors | _ |
Sensor : Electrical Data | |
Operating Voltage Ub | 18 to 27 VDC |
Output Resistance Ra | _ |
Protection Class | _ |
Switching Frequency | 300 Hz |
Sensor : Environmental Conditions | |
EN 60068-2-27, Shock | _ |
EN 60068-2-6, Vibration | _ |
Sensor : Functional Safety | |
MTTF (40 °C) | 715 a |
Sensor : Interface | |
Switching Output | PNP normally open (NO) |
Sensor : Material | |
Housing Material | Brass, nickel-plated |
Material Jacket | PUR |
Material Sensing Surface | PA |
Sensor : Mechanical Data | |
Dimension | Ø 30 x 62 mm |
Installation | for flush mounting |
Size | M30x1.5 |
Sensor : Range/Distance | |
Assured Operating Distance Sa | _ |
Rated Operating Distance Sn | 10 mm |
Real Switching Distance sr | _ |