BALLUFF BES0086 INDUCTIVE STANDARD SENSOR

BALLUFF BES0086 INDUCTIVE STANDARD SENSOR
  • Model: BES0086
$0.00
Ex Tax: $0.00

BALLUFF BES0086 Features


  • Connection: M12x1-Male, 3-pin, A-coded 
  • Operating temperature: -40 to 85 °C
  • IP rating: IP68
  • Shielded and unshielded versions
  • Plug or cable connection
Over 40 Years in Business
Over 40 Years in Business
Successful track record across Canada
Full Engineering Services
Full Engineering Services
A powerhouse to provide consultation, training, and support
Strong Brand Portfolio
Strong Brand Portfolio
Top-notch products from superb global and local suppliers
Advanced Technologies
Advanced Technologies
From legacy and mainstream to advanced Industry 4.0

BALLUFF BES0086 Introduction


Balluff BES standard inductive sensors for detecting electrically conductive metallic objects are robust and reliable. With a wide range of over 500 model series, we offer the right inductive sensor for every application.

The technology, which is in use worldwide, has an optimum price/performance ratio and can also be delivered in a short amount of time even in large quantities.

BALLUFF BES0086 Certifications

    

Sensor : Basic features
Approval/Conformity CE, UKCA, cULus, WEEE
Basic standard IEC 60947-5-2
Sensor : Display/Operation
Function Indicator Yes
Power Indicator No
Sensor : Electrical Connection
Cable diameter D _
Cable length L _
Number of conductors _
Sensor : Electrical Data
Operating Voltage Ub 10 to 30 VDC
Output Resistance Ra 33.0 kOhm + D
Protection Class II
Switching Frequency 2000 Hz
Sensor : Environmental Conditions
EN 60068-2-27, Shock Half-sinus, 30 g , 11 ms
EN 60068-2-6, Vibration 55 Hz, amplitude 1 mm, 3x30 min
Sensor : Functional Safety
MTTF (40 °C) 465 a
Sensor : Interface
Switching Output PNP normally open (NO)
Sensor : Material
Housing Material Brass, Nickel-free coated
Material Jacket _
Material Sensing Surface PBT
Sensor : Mechanical Data
Dimension Ø 18 x 66 mm
Installation for flush mounting
Size M18x1
Sensor : Range/Distance
Assured Operating Distance Sa 4.0 mm
Rated Operating Distance Sn 5.0 mm
Real Switching Distance sr 5 mm