BALLUFF BES02FC INDUCTIVE STANDARD SENSOR
- Model: BES02FC
BALLUFF BES02FC FEATURES
- Connection: M12x1-Male, 4-pin, A-coded
- Operating temperature: -25 to 70 °C, Temperature drift max. (% Sr) > 15% valid from 50 to 70 °C
- IP rating: IP68
- Shielded and unshielded versions
- Plug or cable connection
BALLUFF BES02FC INTRODUCTION
Balluff BES standard inductive sensors for detecting electrically conductive metallic objects are robust and reliable. With a wide range of over 500 model series, we offer the right inductive sensor for every application.
The technology, which is in use worldwide, has an optimum price/performance ratio and can also be delivered in a short amount of time even in large quantities.
As an Authorized Distributor of BALLUFF, Manufacturers Automation Inc. (ManuAuto) offers a wide variety of Industrial Automation and Communication products across North America, including Canada (Ontario, Toronto) and the US. Buy BALLUFF BES02FC INDUCTIVE STANDARD SENSOR online at a competitive price, with on-time delivery and fast shipping services. Our certified engineers are always available to support you.
You can also find the BES060U and BES060T models in the BALLUFF Inductive Standard Sensors.
BALLUFF BES02FC CERTIFICATIONS
Inductive Sensors : Interface | |
Output Characteristic | PNP normally open (NO) |
Inductive Sensors : Electrical Connection | |
Connection | M12x1-Male, 4-pin, A-coded |
Polarity Reversal Protected | Yes |
Inductive Sensors : Electrical Data | |
Protection Class | II |
Ripple | 15 % |
Operating Voltage Ub | 10 to 30 VDC |
Current (Ie) | 200 mA |
Inductive Sensors : Range/Distance | |
Measuring Range | 4 mm |
Assured Operating Distance Sa | 3.2 mm |
Real Switching Distance sr | 4 mm |
Inductive Sensors : Physical and Environmental Characteristics | |
Dimension | Ø 12 x 70 mm |
Weight | - |
Installation | non-flush |
Operating Temperature | -25 to 70 °C |
Housing | Stainless steel |
IP Rating | IP68 |
Tightening Torque | 20 Nm |
MTTF | 850 a |