BALLUFF BOS01Y9 DIFFUSE AND THROUGH-BEAM/ THROUGH-BEAM SENSOR
BALLUFF BOS01Y9 DIFFUSE AND THROUGH-BEAM/ THROUGH-BEAM SENSOR
- Model: BOS01Y9
$0.00
Ex Tax: $0.00
Over 40 Years in Business
Successful track record across Canada
Full Engineering Services
A powerhouse to provide consultation, training, and support
Strong Brand Portfolio
Top-notch products from superb global and local suppliers
Advanced Technologies
From legacy and mainstream to advanced Industry 4.0
Introduction
Photoelectric sensors check presence, shape, color, distance, and thickness - optimized for robotics, automation, assembly, and handling. They are real experts with various strengths: detecting and counting parts, monitoring stack heights, through-glass detection, aligning small parts, detecting marks, fill level detection, and much more!
Certifications
Features
- Connection: Cable with connector, M8x1-Male, 3-pin, 0.20 m, PUR
- Operating temperature: -5 to 55 °C
- IP rating: IP67
- Series: Q08M
- Principle of optical operation: Through-beam sensor (receiver)
- Range: 0 to 2.2 m
- Part recognition and counting
- Stack height monitoring
- Detection through glass
Sensor : Basic features | |
Approval/Conformity | CE, UKCA, cULus, WEEE |
Basic standard | IEC 60947-5-2 |
Sensor : Display/Operation | |
Function Indicator | _ |
Power Indicator | _ |
Sensor : Electrical Connection | |
Cable diameter D | 3.00 mm |
Cable length L | 0.2 m |
Number of conductors | _ |
Sensor : Electrical Data | |
Operating Voltage Ub | 10 to 30 VDC |
Output Resistance Ra | _ |
Protection Class | _ |
Switching Frequency | 500 Hz |
Sensor : Environmental Conditions | |
EN 60068-2-27, Shock | Half-sinus, 30 g , 11 ms, 3x6, Half-sinus, 100 gn, 2 ms, 3x8000 |
EN 60068-2-6, Vibration | 10 to 2000 Hz, amplitude 1 mm, 30 gn, 3x5 h, 10 to 55 Hz, amplitude 1 mm, 3x30 min |
Sensor : Functional Safety | |
MTTF (40 °C) | 972.7 a |
Sensor : Interface | |
Switching Output | PNP normally closed (NC) |
Sensor : Material | |
Housing Material | Zinc, Die casting, nickel-plated |
Material Jacket | PUR |
Material Sensing Surface | PMMA |
Sensor : Mechanical Data | |
Dimension | 8 x 44 x 8 mm |
Installation | _ |
Size | _ |
Sensor : Range/Distance | |
Assured Operating Distance Sa | _ |
Rated Operating Distance Sn | 2.2 m |
Real Switching Distance sr | _ |